Ultimail
diagnostic code diagnostic message remedy
Warning!
Information contained in this document is propritary and the sole property of
Francotyp-Postalia.
This information is confidental and for internal use only. Any disclosure, transmittal or
reproduction to a second party will be procecuted. Francotyp-Postalia reserves the right to
take action, to the fullest extend allowed by law, against both the party discloses
Francotyp-Postalia's proprietary information and the party that recieves it.
ISS international service support
created : 20.11.2007 19:33 Ultimail
Seitenansicht 0
1 2 3 4 5 6 ... 41 42

Inhaltsverzeichnis

Seite 1 - Ultimail

Ultimaildiagnostic code diagnostic message remedyWarning!Information contained in this document is propritary and the sole property of Francotyp-Posta

Seite 2

C156Internal error: Letter started but notcompleted. => C: insert letter againC157Internal error: Process steps notrecognized.=>C: switch FM off

Seite 3

D007 0000 00190000 0005It can be a problem in machines with oldSD SW. make a SD SW update. The actuell version can be checked in the SAD report unter

Seite 4

D116Security module communication errorSecurity device is not plugged in the right way or is defect.Remedy:Verify position of security device and perf

Seite 5

E110Letter in feeder letter transport. => C: remove letters / E: check sensorsE111Letter in sealer letter transport. => C: remove letters / E: c

Seite 6

E117Letters jammed! Please remove letters.Letter Jam/ sensor blocked=> C: a) remove jam (eject roller box), b) does the customer use oversized enve

Seite 7

E126Unable to calibrate the sensor for controlof print starting point (LS3).Letter jam / print start sensor dirty => C: remove letters from letter

Seite 8

E127 xxx2 xxxxxxxx xxxxleft cartridge => HP-ASIC to hot (<142°C)machine is blocked => C: exchange cartridge, install again => T: run conta

Seite 9

E127 xxxx xxx2xxxx xxxxright cartridge => HP-ASIC to hot(<142°C) machine is blocked => C: exchange cartridge, install again => T: run cont

Seite 10

E127 xxxx xxxxxxx xxx5right cartridge => incorrect CP-chip (or nochip) manipulation?=> C: exchange Cartridge, install cartridge again=> T: ru

Seite 11

E127 xxxx xxxxxxx5 xxxxleft cartridge => incorrect CP-chip (or nochip) manipulation?=> C: exchange Cartridge, install cartridge again=> T: ru

Seite 12

diagnostic code diagnostic message remedypictogram legend: The following notes only provides information. In most noerror has occuredCustomer and Hotl

Seite 13

E132The sealer drive is not running.Microswitch of sealer is not toggled correct => C: release roller transport of sealer and close it againE133The

Seite 14

E140Unable to transfer data to print cartridges.1: Print cartridge status information, asunder E1272: Consumable protection statusinformation, as unde

Seite 15

E147temperature of print cartridges to highUnacceptable temperature of print cartridges (> 55°C) is detected. Print quality will be effected.Subcod

Seite 16

E153Warm up the cartridges missed, pleaseexecute 'change cartridges' !Contact problems / faulty Inkjet cartridges / current not sufficient /

Seite 17

F102Interface card not found => C: confirm Error, start working, call Service, because after the next power up the message appearsagain.=>T: Ch

Seite 18

G200No print image data available!=> T: install complete images (mabe FP-card is nessecary?)G202Unrecognized offset value in print imagedata!This c

Seite 19

G237There are too many logos to be loaded!Select fewer or delete some in advance!=> Please think about the max. number of clicheesG238There are too

Seite 20

G250Print image data structure error! Width ofpixel header does not fit in PicPart => T: load another full image via chip card or PMD customizing.(

Seite 21

G259An error occurred while generating the IDmatrix code. It may only occur underdevelopment.Too much data provided for barcode => Inform R&D d

Seite 22

G267string too longString is too long. String can not be printed. Please call FP-service.The string-verification is activated at chliche version >=

Seite 23

A001FM is not in READY modeC: Insert Master cardA002no modem detectedT: Run modem test in SERVICE MODEA100A100 followed by C303 memory errorNV-Rammemo

Seite 24

H104Security module: Command cannot beperformed!If: 00000001 00010216, then HS-LOOP isnot closedSecurity Module not plugged / defective =>T: plug S

Seite 25

H116In Canada muss die CreationTimeinnerhalb eines Batches (zwischen zweiPVDs) aufsteigend sein. Dies ist hier nichtder Fall. Hinweis für BenutzerZeit

Seite 26

M103Postage table returning Value too high“error => load actual rate tableM104Postage table returning Invalidcombination” error => C: load valid

Seite 27

M131The active rate table does not supportSSB.Please run TELESET to download thelatest rate table.Operator tried to print SSB with a rate table that d

Seite 28

M138rate calculation - product not allowedYour selection will not be supported in the current mode of the meter.At this time only valid for Canada: t

Seite 29

O004Line is busy.Customer: try againT: PBX system use wrong toneO006no connectioncheck phone system, try to contact the TDC/FPI via telephoneO007 XXXX

Seite 30

O007 XXXX XXXX0000 0003general error by connecting the FPI- noanswer (modem) Please check the modem configuration1) dial parameter2) extension #3) pho

Seite 31

O007 0000 00030000 0005=> communication error between FM ->FPIbad (noise) phone line?O007 0000 00040000 0005=> Service not availebletest the

Seite 32

O007 0000 00110000 0005=> invalid reset amountplease choice a other amount (steps of 10)O007 0000 00120000 0005=> unvalid transactionPlease cont

Seite 33

O007 0000 001A0000 0005=> Meter is not released by the postalauthoritycontact your FPI adimO007 0000 001B0000 0005=> Meter is sign offcontact yo

Seite 34

C100Process initialization failed.root causes will be highlighted at subsequent diagnosis codesC101Insufficient credit loaded to securitymodule.No mon

Seite 35

O007 0000 00230000 0005=> R3 overflownormally impossible! contact your FPI adminO007 0000 00240000 0005=> wrong teleset keys (Kfix0, Kfix1, Kvar

Seite 36

O043TDC message: Meter is is lockedHotline: Please ask Data center admin about the lockingThis warning is supported from SW 03.01.02 and higherO044The

Seite 37

O102Step width for teleset not observedPlease select an other reset value (in 10 imcrements)O103Register 1 overflowNormally impossibleO104Register 3 o

Seite 38

C103 0000 0006xxxx xxxxSD state is not invalidSD state is WITHDRAWNCustomer may have withdrawn the meter by itself?=> T: run re-initializing by usi

Seite 39

C104 xxxx xxxx0000 0005machine is not readythe autorization failedrepeat autorizationC104 xxxx xxxx0000 0006machine is not readythe accounting process

Seite 40

C108No communication with security module Security Module not plugged / defective should be done by technicain: 1) run SD echo test and SD selftest in

Seite 41

C114Battery B (extern) is too low. Franking isimpossible.Subcode 1 show actual batt. Voltage inmV (<2950mV) => C: replace battery, only use orig

Seite 42

C122In the parameters of the batch commandsis an error!e.g.ProductCode = 0letterId = 0A parameter transferred in the batch commands from external devi