D007 0000 0019
0000 0005
It can be a problem in machines with old
SD SW.
make a SD SW update. The actuell version can be checked in the SAD report unter APP SW
VERSION!
This update can be done only in the workshop, because the SD must be in the state initialized
(FP-card requried!)
D032
Don't find account
It's only a warning, please confirm with ENTER
make a software update 02.36.00 and higher
see technical bulletin 11
D036
Account didn't exist => maybe chip card
contact problem
check the chip card 8direction, clean, correct one?)
D037
No access to account currently set=>
Contact problem with chip card
C: check chip card, insert chip card with chip to the bottom, insert chip card beyond the pressure point
D043
Meter is locked in TeleportoDataCenter
Please contact the dataCenter administrator
D109
No credit in current account.
C: assign credit to appropriate account, if necessary run TELESET
D113
Low postage warning for current account.
Credit below set warning threshold.
=> C: assign credit to appropriate account
D114
No card when attempting to set postage
value
Contact problem with chip card
=> C: check chip card, insert chip card with chip to the bottom, insert chip card beyond the pressure
point
D115
Internal user interface error => Error in user interface
C: send diagnostic data
error is fixed with SW 02.39.07 and higher
deselect optimizing the rate calculation
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 11 Ultimail